Wafaiya YanbuRCJY answers
09

Design Requirements · Requirement 9 of 27

Sustainability and energy-efficiency solutions

Roof PV about 2.1 GWh/yr, 17 PV carports (476 kWp), SBC 601 envelope (U ≤ 0.34, SHGC ≤ 0.25), TSE irrigation, 26 EV charging and 52 EV-ready bays.

✓ CompliedRC presentation REV09 · p. 23–24, 94, 131

Answer

PV: 6,246 m2 of panels on the upper roofs and annex roof - 1.52 GWh/yr at 15 % efficiency, about 2.1 GWh/yr with 21 %-class modules (Forma; 10,409 m2 of roof receives about 2,000 kWh/m2/yr).

Envelope to SBC 601: walls U <= 0.34 W/m2K; low-E solar-control glazing (target SHGC <= 0.25, U <= 1.9 W/m2K); room WWR 36 %; khatam screens 35-45 % open on the west.

Water: water-efficient fittings, TSE-ready drip irrigation for 4,003.78 m2 of native planting. HVAC: central chilled water with heat recovery.

Surface parking: 17 PV carport canopies over 141 bays, 476 kWp, about 880 MWh/yr. EV: 26 charging bays (incl. 2 DC fast and 1 accessible) and 52 EV-ready bays (LEED LT c5).

Key data and sources

Each figure with the drawing, study or standard it comes from.

ItemValueSource
PV area / yield6,246 m2 / about 2.1 GWh/yr (21 % modules)Autodesk Forma
Wall U-value<= 0.34 W/m2KSBC 601
GlazingLow-E DGU, SHGC <= 0.25, U <= 1.9 W/m2K, VLT about 45 %SBC 601 target
Room WWR36 % (Option A)WWR study
IrrigationDrip, TSE-ready, 4,003.78 m2 plantingBOQ Bill 15

Drawing evidence – R17 sheets

The latest issued drawings (8 November 2026). Click a sheet to open it full size.

WFY-AR-100
WFY-AR-100Site development and landscape plan
WFY-AR-101
WFY-AR-101Basement floor plan – hotel (incl. tanks, LEED parking)

Where it is in the RC presentation

Wafaiya_Yanbu_RC_Submission_REV09.pdf (135 pages) – click a page to open it full size.

Presentation page 23
Page 23
Presentation page 24
Page 24
Presentation page 94
Page 94
Presentation page 114
Page 114
Presentation page 131
Page 131

Evidence photos

The photos attached to this item in the compliance answer sheet.

Evidence photo 1
Photo 1
Evidence photo 2
Photo 2
Evidence photo 3
Photo 3
Evidence photo 4
Photo 4

References

  • Autodesk Forma solar study; SBC 601 / 602; BOQ 14.H.01 (HVAC); landscape BOQ Bill 15